Wired devices
Driver®Control — the controller that executes the decision
A network controller between the wired biometric readers and the software. Four programmable relays, two digital inputs and support for up to two reading devices.
- 4 × 12 A / 230 V relays
- 2 digital inputs
- Up to 2 readers
Availability
Available from stock
Available from stock. Every inquiry is assessed case by case.
- Delivery
- From stock, lead time on confirmation
- Phone
- +359 2 806 6780
- office@biodit.bg
What it is
Driver®Control is the network controller between BIODIT wired biometric devices and the management software. It works with up to two biometric devices to control a single door or two doors.
It has four programmable relays and two programmable digital inputs. It controls electronic locks, automatic doors, parking barriers and turnstiles, as well as electrical equipment such as lighting, air conditioning, ventilation and elevators. Communication with the software runs over a built-in Ethernet card.
Key features
- Connects to the existing Ethernet network.
- Encrypted Ethernet link with the management software.
- Encrypted communication between reader and controller over the 485 bus.
- Automatic entry/exit mode (anti-passback).
- Configurable relays — bistable or pulse mode, with adjustable timing.
- Configurable digital inputs — trigger or switch.
- Configurable delays for output activation.
- Outputs can be activated directly from the digital inputs.
- Conditional logic for output activation.
- SELV power supply (safety extra-low voltage).
Technical specification
| Category | Values |
|---|---|
| Environment | Operating temperature –10 °C to 45 °C; storage –20 °C to 70 °C; relative humidity 20–80% |
| Power | 12 V DC / 1 A |
| Interfaces | Power jack; RJ45 Ethernet; RS232 for local configuration; 2 digital inputs; 4 relay outputs 12 A 230 V (NC/NO); 2 × RJ45 for the 485 bus to readers |
| Network | 485 bus to readers; Ethernet; online operation only |
| Installation | Interior; surface mounting |
Where Driver®Control sits in the system
In a wired architecture the controller is the heart of the site: readers connect to it and it executes the software’s decision. It is online-only, which makes it a good fit for sites with reliable network connectivity.
Where it is used
- Doors with access control and anti-passback.
- Parking barriers and turnstiles.
- Lighting, air conditioning and ventilation switched by an access event.
- Elevators — floor access control.
Documents
The technical datasheet is provided on request, together with wiring diagrams and support terms.
Ask about your site
Tell us what the controller must drive — a door, barrier, turnstile, lighting or elevator — and we will propose an input/output scheme.